Loft roll, 270 mm between and over joists

A pitched roof with the insulation at ceiling level from the tool's Typical UK roofs group. With the layers below it has a U-value of 0.16 W/m²K, is 282.5 mm thick, and has about 9 kgCO₂e/m² of embodied carbon.

U-value
0.16W/m²K
Overall thickness
282.5mm
Embodied carbon
9kgCO₂e/m²
Fire
Worst class D
Open this build-up in the toolChange layers, check fire and condensation for your own project, and export a PDF.

Against the Building Regulations

New home inU-value limitThis build-up, 0.16
England0.16 W/m²KMeets it
Wales0.13 W/m²KMisses by 0.03
Scotland0.12 W/m²KMisses by 0.04

These are the limits for a single element in a new home. In England a new home usually needs better figures to pass the whole-house target. All UK U-value limits.

Section, drawn to scale

Layers, outside to inside

#Layermmλ, W/mKR, m²K/WkgCO₂e/m²Fire class
1Mineral wool loft roll 0441700.0443.8642.5A1
2Mineral wool loft roll 044
bridged by joists at 600 mm
1000.0441.9332.5A1
3Plasterboard12.50.210.0603.5A2-s1,d0
Total, with surface resistances282.56.2808.5

U-value worked out to BS EN ISO 6946 from the total resistance. Carbon is stages A1 to A3 for the layers.

Moisture and rain

Not checked Cold pitched roofs with insulation at ceiling level are governed by air leakage into the loft, so BS 5250 13.3 says the Glaser method is unsuitable. Make the ceiling airtight and ventilate the loft.

Rain: Not checked for exposure zone 2 (moderate).

Other typical UK roofs

Figures come from the Build-up Atlas's own calculation, with generalised values for typical products, for an England new home with default settings. They are indicative, for design and teaching: check the manufacturer's declared values and the current regulations for your project. Rules and standards last checked 21 October 2026.