27 Profiled metal sheet

A pitched roof with the insulation at the rafters from the tool's Metal roofs group. With the layers below it has a U-value of 0.19 W/m²K, is 241.2 mm thick, and has about 39 kgCO₂e/m² of embodied carbon.

U-value
0.19W/m²K
Overall thickness
241.2mm
Embodied carbon
39kgCO₂e/m²
Fire
A2 or better
Open this build-up in the toolChange layers, check fire and condensation for your own project, and export a PDF.

Against the Building Regulations

New home inU-value limitThis build-up, 0.19
England0.16 W/m²KMisses by 0.03
Wales0.13 W/m²KMisses by 0.06
Scotland0.12 W/m²KMisses by 0.07

These are the limits for a single element in a new home. In England a new home usually needs better figures to pass the whole-house target. All UK U-value limits.

Section, drawn to scale

Layers, outside to inside

#Layermmλ, W/mKR, m²K/WkgCO₂e/m²Fire class
1Profiled steel sheet or panel facing0.7500.00015.2A1
2Mineral wool quilt for built-up metal systems2400.046.0004.5A1
3Steel liner sheet or tray0.5500.00010.8A1
Total, with surface resistances241.26.14038.8

U-value worked out to BS EN ISO 6946 from the total resistance, plus 0.030 W/m²K of corrections for fixings, gaps or brackets. Carbon is stages A1 to A3 for the layers, including 8.3 kgCO₂e/m² for steel rails or purlins.

Moisture and rain

Fails: condensate builds up year on year Up to 27 g/m² at between profiled steel sheet or panel facing and mineral wool quilt for built-up metal systems (part 1 of 24), with some left after 12 months. Surface factor 0.95 (needs over 0.72 and at least 0.75).

Rain: Not checked for exposure zone 2 (moderate).

Other metal roofs

Figures come from the Build-up Atlas's own calculation, with generalised values for typical products, for an England new home with default settings. They are indicative, for design and teaching: check the manufacturer's declared values and the current regulations for your project. Rules and standards last checked 21 October 2026.