26 Metal standing seam

A pitched roof with the insulation at the rafters from the tool's Metal roofs group. With the layers below it has a U-value of 0.19 W/m²K, is 243.8 mm thick, and has about 53 kgCO₂e/m² of embodied carbon.

U-value
0.19W/m²K
Overall thickness
243.8mm
Embodied carbon
53kgCO₂e/m²
Fire
A2 or better
Open this build-up in the toolChange layers, check fire and condensation for your own project, and export a PDF.

Against the Building Regulations

New home inU-value limitThis build-up, 0.19
England0.16 W/m²KMisses by 0.03
Wales0.13 W/m²KMisses by 0.06
Scotland0.12 W/m²KMisses by 0.07

These are the limits for a single element in a new home. In England a new home usually needs better figures to pass the whole-house target. All UK U-value limits.

Section, drawn to scale

Layers, outside to inside

#Layermmλ, W/mKR, m²K/WkgCO₂e/m²Fire class
1Zinc sheet, standing seam0.81100.00017.7A1
2Mineral wool quilt for built-up metal systems2400.046.0004.5A1
3Bitumen felt or roofing membrane20.230.0090.9E
4Profiled steel structural deck1500.00021.7A1
Total, with surface resistances243.86.14953.1

U-value worked out to BS EN ISO 6946 from the total resistance, plus 0.030 W/m²K of corrections for fixings, gaps or brackets. Carbon is stages A1 to A3 for the layers, including 8.3 kgCO₂e/m² for steel rails or purlins.

Moisture and rain

Traces only Under 10 g/m² at most, which the tool treats as negligible. Surface factor 0.95 (needs over 0.72 and at least 0.75).

Rain: Not checked for exposure zone 2 (moderate).

Other metal roofs

Figures come from the Build-up Atlas's own calculation, with generalised values for typical products, for an England new home with default settings. They are indicative, for design and teaching: check the manufacturer's declared values and the current regulations for your project. Rules and standards last checked 21 October 2026.