36 Concealed membrane

A flat roof from the tool's Concrete roofs group. With the layers below it has a U-value of 0.27 W/m²K, is 468 mm thick, and has about 131 kgCO₂e/m² of embodied carbon.

U-value
0.27W/m²K
Overall thickness
468mm
Embodied carbon
131kgCO₂e/m²
Fire
Worst class E
Open this build-up in the toolChange layers, check fire and condensation for your own project, and export a PDF.

Against the Building Regulations

New home inU-value limitThis build-up, 0.27
England0.16 W/m²KMisses by 0.11
Wales0.13 W/m²KMisses by 0.14
Scotland0.12 W/m²KMisses by 0.15

These are the limits for a single element in a new home. In England a new home usually needs better figures to pass the whole-house target. All UK U-value limits.

Section, drawn to scale

Layers, outside to inside

#Layermmλ, W/mKR, m²K/WkgCO₂e/m²Fire class
1Paving slabs on supports50–0.00015.0A1
2XPS board2000.0345.88225.7E
3Bitumen felt or roofing membrane50.230.0222.4E
4Reinforced concrete2002.30.08786.4A1
5Plaster, dense130.570.0232.0A1
Total, with surface resistances4686.154131.5

U-value worked out to BS EN ISO 6946 from the total resistance, plus 0.110 W/m²K of corrections for fixings, gaps or brackets. Carbon is stages A1 to A3 for the layers.

Moisture and rain

Free of interstitial condensation No condensation in any month (Heathrow (London), 1 in 10 year). Surface factor 0.93 (needs over 0.72 and at least 0.75).

Rain: Not checked for exposure zone 2 (moderate).

Other concrete roofs

Figures come from the Build-up Atlas's own calculation, with generalised values for typical products, for an England new home with default settings. They are indicative, for design and teaching: check the manufacturer's declared values and the current regulations for your project. Rules and standards last checked 21 October 2026.