22 Sealed panels, insulated GRP

An external wall from the tool's Polymer walls group. With the layers below it has a U-value of 0.26 W/m²K, is 110 mm thick, and has about 152 kgCO₂e/m² of embodied carbon.

U-value
0.26W/m²K
Overall thickness
110mm
Embodied carbon
152kgCO₂e/m²
Fire
Worst class E
Open this build-up in the toolChange layers, check fire and condensation for your own project, and export a PDF.

Against the Building Regulations

New home inU-value limitThis build-up, 0.26
England0.26 W/m²KMeets it
Wales0.18 W/m²KMisses by 0.08
Scotland0.17 W/m²KMisses by 0.09

These are the limits for a single element in a new home. In England a new home usually needs better figures to pass the whole-house target, about 0.18 for walls. All UK U-value limits.

Section, drawn to scale

Layers, outside to inside

#Layermmλ, W/mKR, m²K/WkgCO₂e/m²Fire class
1GRP panel skin50.30.01768.8E
2Polyurethane foam core1000.0283.57113.9E
3GRP panel skin50.30.01768.8E
Total, with surface resistances1103.775151.6

U-value worked out to BS EN ISO 6946 from the total resistance. Carbon is stages A1 to A3 for the layers.

Moisture and rain

Condenses in winter, dries by summer Up to 14 g/m² at between grp panel skin and polyurethane foam core (part 1 of 15), all of it drying out over the year. Surface factor 0.93 (needs over 0.71 and at least 0.75).

Rain: Face-sealed for exposure zone 2 (moderate).

Other polymer walls

Figures come from the Build-up Atlas's own calculation, with generalised values for typical products, for an England new home with default settings. They are indicative, for design and teaching: check the manufacturer's declared values and the current regulations for your project. Rules and standards last checked 21 October 2026.